Technical Datasheet SOLOCRET®-50 Non slump levelling compound up to 50 mm, rapid setting
Material number
Contents
Unit of quantity
Packaging
Colour
205440001
25
KG
Bag
Grey
Product features CT-C25-F4 in accordance with DIN EN 13813 Non slump Layer thicknesses von 2 mm bis 50 mm Rapid setting Low stress Universally applicable
Advantages Fine surface rapid construction progress
Areas of application To compensate for and level uneven walls and substrates To establish angled trowelling Can be used for damp and wet areas For interior and exterior use
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 1/4
27/07/2023
Technical Datasheet SOLOCRET®-50 Existing test certificates Reaction to fire
Technical Data Material properties Product components Base material
Consistency Bulk density of fresh mortar Flexural strength (28 days, DIN EN 13813) Compressive strength (28 days, DIN EN 13813) Classification of the reaction to fire in accordance with DIN EN 13501-1
1 component system Special cement Cementitious aggregates Additive Powdered approx. 1.8 kg/dm³ ≥ 4 N/mm² ≥ 25 N/mm² A1
Mixing Mixing time Maturing time Water addition
approx. 3 - 5 minutes approx. 3 minutes from 4 l to 4.5 l
Application Substrate temperature Pot life Consumption pro m² and mm layer thickness Foot traffic after Ready for covering with tiles Application temperature Hardening time / full resilience
from 5 °C to 25 °C approx. 30 minutes approx. 1.5 kg/m² approx. 3 hours approx. 3 hours from 5 °C to 25 °C approx. 28 hours
Application technology Aids/tools Flat trowel Stirrer Clean mixing bucket
Suitable substrate Firmly adhering tiled finishes Concrete, cement screed (CT), floor levelling compounds, calcium sulphate screeds (CA, CAF), mastic asphalt screeds (AS), magnesia screeds (MA) Cement-based plaster, gypsum plaster, cement-lime plaster, lightweight plaster Tile bearing elements, gypsum fibre boards, gypsum boards, raised floors, cement and fibre cement boards, decoupling mats & panels, dry screeds Bonded waterproofing; the suitability of the substrate must be checked and observed, taking into account the planned water impact class of DIN 18534 and DIN 18531.
Substrate preparation Requirement for substrate 1. 2. 3. 4. 5. 6.
Dry Load-bearing Firm Grippy Free of cracks Free of adhesion inhibiting substances
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 2/4
Technical Datasheet SOLOCRET®-50 Measures for substrate preparation The substrate must correspond to the payloads associated with the load-bearing capacities in accordance with DIN EN1991-1-1.
Preparing the surface 1. 2. 3. 4.
Check the application substrate and determine the moisture content using the CM method. Remove impurities, adhesion-reducing substances and binder accumulations/laitance layers. Prime absorbent substrates with ASO-Unigrund-GE or ASO-Unigrund-K. Prime non-absorbent substrates with ASO-Unigrund-S.
Moisture content of the CM measurement
Usage Mixing 1. 2. 3. 4.
Put the water into a clean mixing bucket and mix with the powder component with a stirrer to produce a homogeneous, lump-free mass. The mixing time is ca. 3 - 5 minutes. After a settling period of ca. 3 minutes, thoroughly homogenise the compound again. Do not mix more material than can be applied during the pot life.
Application 1. Apply SOLOCRET®-50 to the primed substrate, and use a suitable tool to distribute it evenly during the pot life. 2. SOLOCRET®-50 can be applied in a single application step up to a layer thickness of 50 mm. Up to a layer thickness of 100 mm in damaged areas. 3. Smooth after around 30 minutes if required. 4. A grid float can be used for grid floating after around 60–80 minutes (depending on the substrate, ambient conditions and layer thickness). 5. Any potential skimming using SOLOCRET®-50 should be carried out when the first layer is firm but is still somewhat damp, as can be seen by the darker colour. Do not exceed the maximum layer thickness mm!
Cleaning tools Clean tools thoroughly with water after use.
Storage conditions Storage Store in a cool and dry place. Min. 12 months in the original canister. Promptly use opened canister.
Disposal Product leftovers can be disposed of in accordance with disposal code AVV 17 01 01.
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 3/4
Technical Datasheet SOLOCRET®-50 Notes Do not use in the pressure water range! Direct contact between cement mortar and magnesite screeds leads to the destruction of the magnesite screeds through a chemical reaction known as "magnesite pouring". Moisture pressure from the rear of the substrate must be prevented through appropriate measures. Mechanically roughen up the magnesite substrate and prime with ASODUR®-GBM epoxy resin. While the coat is still fresh, apply plenty of quartz sand with a grain size of 0.5–1.0 mm. Perform the laying work after a further waiting time of approx. 12 - 16 hours. Remove the unbound quartz sand meticulously. For calcium sulphate screeds, the carbide method moisture content may not exceed 0.5% if there is no floor heating system, or 0.3% if there is a floor heating system at the time of levelling with SOLOCRET®-50. Prime the calcium sulphate screed with ASODUR®-GBM and scatter quartz sand (Ø 0.5–1.0mm). Then remove the unbound quartz sand thoroughly and then level with SOLOCRET®-50 to a layer thickness of von 2 mm bis 50 mm. The following moisture migration should be avoided. We recommend SOLOPLAN®-30-CA for levelling calcium sulphate binded substrates, e.g. calcium sulphate screeds. Border, field, building separation and movement joints should be carried over to or installed at the designated location; suitable means such as RD-SK50 edging strips should be used to detach them! Crack control joints should be cut in after the SOLOCRET®-50 has hardened to the level of up to a third of the introduced layer thickness! Do not add water or new mortar to existing SOLOCRET®-50 mortar that has already set in order to make it workable again. (Risk of inadequate strength development) Protect surfaces that are not to be treated from the effects of SOLOCRET®-50!
Planning, inspection of substrates and building site circumstances, laying, grouting and subsequent care of the work must be done in accordance with the relevant DIN standards and recognised rules of technology (e.g. the ZDB sheets of the Zentralverband Deutsches Baugewerbe e.V.) in the latest version. Observe applicable safety data sheet! GISCODE: ZP1 Annotations Conformity / Declaration / Verification
The rights of the buyer with regard to the quality of our materials are based on our terms and conditions of sale and delivery. Our technical advice team will be happy to advise you in the case of requirements that exceed the scope of the application described here. In order to be binding, a legally binding written confirmation is required. The product description does not release the user from a duty of care. Lay a test area in the event of uncertainty. This version becomes invalid in the event of a new version being issued.